360 Degree Ceiling Mount PIR Presence Sensor / Occupancy Sensor -Dual Channel for HVAC and Lighting Control (DIM) - Conference Room

Presence Control PRO IR Quattro HD COM2 (1-10V DIM : Swiches and Controls Light - Analog Ballast)


Detection Zone
Reach: 8 - 20 mts. adjustable in a square detection pattern to eliminate any blind or undetected areas. The fine / small motion area is 8x8 mts. (64 sq.-mts.)
Mechanically Adjustable Reach
The square detection zone can be mechanically adjusted with a potentiometer for specific detection in the area.
Technical Highlights The sensor has 2 channels, one for the 1-10V DIM analog interface by means of a constant lighting controller. The second channel operates the heating, ventilation and air conditioning systems in relation to presence only.
Lighting Controller A pre-selected brightness level can be maintained. This function allows the lighting level at 10% after the stay 'ON' time elapses when no movement is detected. This feature can also be interfaced with the ambient lux level.
Applications Conference rooms, Training Halls and Meeting rooms, Office Cabins, Classrooms, Staff Rooms
Technology Passive Infrared / PIR - 4800 switching zones and 13 detection levels for sensing small movements normally found in a seated postion, with 4 highly sensitive pyro detectors. The digital technology improves signal evaluation without switching errors.
Mounting
Ceiling Mount PIR Presence Sensor - Mounting Height: 2.5 mts to 10 mts.
Output
Lighting Channel : 1000 W uncorrected inductive loads like t5 lights, CFL, fluorescent lamps/tubes with electronic ballasts

Controlled Output : 1-10 V, 50 electronic ballast max. (100 mA max.)

HVAC Channel : 1A max. for connection to a relay or contactor to switch HVAC loads.
Lighting Channel
Output No. 1

Time Setting
:: 30 sec. - 30 minutes

:: Automatic time adjustment - The sensor analyzes the movement and automatically adjusts the time delay for the user.

:: Basic Brightness : 0 - 30 minutes for 10% basic brightness level. This time setting can maintain lux level of the lamp when no movement is detected. As soon as a person is present the light intensity is increased to the pre-selected brightness level.
HVAC Channel
Output No. 2

Time Setting
:: 1 minutes. - 2 hours - Manually adjustable - switch 'ON' delay

:: 0 sec. - 10 minutes, Automatic time adjustment - switch 'OFF' delay. The room surveillance function allows the user to set a delay time before starting the HVAC loads. This feature automatically adjusts the time for the starter based on the movement pattern
Lux setting facility
Lux level with Twilight setting can be done through a hand-held remote control. There are 6 typical room situations to choose from. Constant light control with mixed light measurement
Master & Slave Individual luminaires can be hardwired for connecting them in parallel which is suitable for the Master & Slave Operation and enhancement of the zonal coverage of detection.
Handheld Remote Control
Infra Red Control available for parameter settings
Supply
230V AC 50Hz
IP Rating IP 54 with surface mounting and IP 20 with recessed mounting.
Mounting Adapters
Clamping-type ceiling adapter Control PRO UP BoxSurface-mounting adapter





Control PRO AP Box (IP 54)

How We Work

Sensor Planning : Know More

Potential Savings Prediction : Know More

Site Survey : Know More

Energy Saving Calculator : Know More

Quick Enquiry

*Are Mandatory fields

*Name

*Email Id

*Phone No

Comments